PHOTO #4 Removed tube sample
NOTE: Failure in tube
PHOTO #4
Bottom Half - Note Minimal Corrosion
Liquid
PHOTO #5 Severe groove depth adjacent
to edge of support
PHOTO #6
PHOTO #7
PHOTO #8
PHOTO #5
Top Half - Note Corrosion
PHOTO #6
Bottom Half - Note Minimal Corrosion
PHOTO #7 Cross Section
Tube split to show top & bottom
Left & right sides show minimal corrosion. Liquid covered.
Inner left & right (top circumference of tube) show heavy corrosion. Liquid/Vapor.
PHOTO #8
Top Half - Note Corrosion
Unexpected Tube Failure in
HDS Stripper OVHD Air Cooler
chronicle companion images
PHOTO #2
NOTE: Close up of Failure
PHOTO #1
Top half of tube looking at failure
PHOTO #3
Top Half of Tubing - Note Corrosion
Liquid/Vapor
SMR Tube Failure
chronicle companion images
IMAGE#2
SMR Plant Diagram
IMAGE#3
RFET Inspection Results
IMAGE#1
View of Top Tube Sheet & Suspect Heavily Corroded Tubes
(in red)
IMAGE#4
RFET Inspection Result Depicted in 3D
IMAGE#5
View of Failure - 8"inches above U-bend
IMAGE#6
INSPECTION PHOTOS
right click to download images