chronicle companion images

Acid Carryover

PHOTO #1
Severe OD corrosion/wastage at the bundle top rows front
NOTE: Severe Wastage
PHOTO #2
Tie rod spacer corrosion/wastage at the bundle shell inlet deflection plate
PHOTO #3
Close-up of severe OD corrosion/wastage to failure
  • Black Facebook Icon
  • Black Twitter Icon
  • Black Google+ Icon
  • Black Instagram Icon
About & Subscribe
PHOTO #4
Representative of OD corrosion wastage and pitting found in heavy concentrations along tube lengths, bundle top, center region, condensing zone
PHOTO #5
Representative of OD corrosion wastage and pitting found in heavy concentrations along tube lengths, bundle top, center region, condensing zone
PHOTO #6
Representative of OD corrosion wastage and pitting found in heavy concentrations along tube lengths, bundle top, center region, condensing zone.