PHOTO #4 Removed tube sample
NOTE: Failure in tube
PHOTO #4
Bottom Half - Note Minimal Corrosion
Liquid
PHOTO #5 Severe groove depth adjacent
to edge of support
PHOTO #6
PHOTO #7
PHOTO #8
PHOTO #5
Top Half - Note Corrosion
PHOTO #6
Bottom Half - Note Minimal Corrosion
PHOTO #7 Cross Section
Tube split to show top & bottom
-
Left & right sides show minimal corrosion. Liquid covered.
-
Inner left & right (top circumference of tube) show heavy corrosion. Liquid/Vapor.
PHOTO #8
Top Half - Note Corrosion
Unexpected Tube Failure in
HDS Stripper OVHD Air Cooler
chronicle companion images
PHOTO #2
NOTE: Close up of Failure
PHOTO #1
Top half of tube looking at failure
PHOTO #3
Top Half of Tubing - Note Corrosion
Liquid/Vapor
Surface Condenser - Deaerator Problems
chronicle companion images
IMAGE #3
Heavy deposit layer – Calcium deposits
Plugging of the deaerator has the following effects on operation:
​
-
Poor flow characteristics throughout the bundle matrix
-
Loss of vacuum
-
Overload of secondary ejector exchangers
-
Poor removal of non-condensable gasses
-
Accelerated corrosion due to poor non-condensable removal
-
Provide inadequate boiler feed pump suction head
-
Disrupt flow charactistics throughout the condenser
About & Subscribe
IMAGE #1&2
View of bottom half of surface Condenser
with both deaerators fully plugged (Tapered plugs)
IMAGE #4
View of tube sheet map with associated corrosion depths
INSPECTION PHOTOS